- Brand: Triton
- SKU / MPN: Triton Cara
- Categories: Triton Shower Spares, Triton Cara Shower Spares
All available shower spares/replacement parts to fit the Triton Cara 1st generation (Cara).
Use the main diagram to identify the shower spare(s) you need to replace. Then use the table below to locate your relevant part(s).
Not what you're looking for? Try our unique Shower Spares Finder.
Need any help identifying the fault with your shower? Take a look at our handy Fault Finder page.
Otherwise please feel free to contact us.
-
There are 8 currently available spares for the Triton Cara 1st generation (Cara).
These are sorted by diagram reference first (if available) and then by product code in numerical / alphabetical order:
Discontinued -
Do you have a question about the Triton Cara 1st generation (Cara)?
Click the button below to send a question to one of our expert members of staff and we will email you back a direct response. If we feel the information might be useful to other customers, we will also show your question below for others to see.
-
Hi I have a Triton Cara. When we switch off we have water running from the shower head. We've even switched off the power switch and it still doesn't shut off properly.....occasionally the water is gushing out almost like the shower is still switched on. We can get the water back to dripping only. Any advice as to what the problem might be would be appreciated.
Hello, the solenoid 83300450 is jammed open, if you replace the solenoid the problem should be resolved
-
Hi, I have a Triton Cara 10.5 and when we put it on it only works for about 2 minutes then knocks off. Any ideas? Thanks
Hi
If the shower is shutting off the solenoid it at fault item 83300450
Kind regards -
Hi I have a Triton Cara 10.5 w this morning will only get hot on a very high setting soon as I turn it down it goes cold can you help
Hello, it sounds like the pressure switch dropping out, you either have a low water pressure problem or the stab valve is faulty, part number P07810800
-
Had a new wc pan connector fitted. The plumber left the main water tap on full open position (full pressure). Triton Cara 9.5w unit worked first time but then water started gushing out of the PRD (Pressure Relief Device - 82800450). Tried to switch on and off but the problem still persists. What could have gone wrong? And what needs to be done to stop the water gushing out of PRD?
Hello, the prd needs to be replaced, it has probably blown as there is more flow rate now the stop tap has been opened fully, perhaps the shower head is slightly blocked causing too much back pressure. PRD is part number 82800450
-
Hi I have had a triton cara for 20 months and it now runs too hot, even at low settings .( It it is still possible to run it cold ) however any other setting ,and it goes straight to too hot. ( very hot)
Hello, overheating is nearly always caused by a partially blocked shower head or hose.
the slower the flow is the hotter the water gets -
Ive had a triton cara shower for about 2years and the shower has started to constantly drip after its turned off. Does a washer need changing what do you think
Hello, it will need a new solenoid valve 83300450
-